Self-Starting Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Speed
BS-L100
Land Use
Common Units, Standby Unit, Emergency Crew
Low Noise
AC Rotating Exciter
Lovol
Stamford
Smartgen,Deepsea...
Electric Start
22kw - 163kw
Optional
as Per Request
50Hz/60Hz
400V 380V
Packed in Plywood Cases or Wooden Cases or Foam, E
As for power
BOSSPOWER
China
85021200
100 Sets / Month
US$ 5500/Piece 1 Piece(Min.Order) | Request Sample
PRODUCT DESCRIPTION |
Engine Parameter: | |
Manufacturer/Model: Aspiration: Fuel System: Cylinder numbers Displacement: Bore x Stroke Compression Ratio: Max. Power: Governing System: | LOVOL 1006TG2A, 4 stroke Turbocharged, Air/air cooling PN Fuel Pump, 6 cylinders in-line 5.9 L 105 x 127 mm 17.5 : 1 102KW / 139HP Electrical |
Exhaust System | |
Exhaust Gas Flow: Exhaust temperature: Max. Allowed Back Pressure: | 17.9 m³/min 535 ºC 10 KPa |
Intake System | |
Max. Allowed Pressure: Gas Volume: Air Flow: | 6.2 kPa 7.8 m³/min 298 m³/min |
Fuel System | |
100% Load (Prime): 75% Load(Prime): 50% Load (Prime): | 24L/h 18L/h 12L/h |
Lube System | |
Oil Capacity: Oil Consumption: Bottom shell oil capacity: Oil Pressure at rated speed: | 16.4 L ≤4g/kw.h 14.3 L 350 kPa |
Cooling system | |
Coolant Capacity: Thermostat: Max. Water Temperature: | 26 L 82-93ºC 104ºC |
Alternator Parameter: Basic Information | |
The alternators meet the standards of: GB755, BS5000, VDE00530, NEMAMG1-22,IED34-1,CSA22.2 and AS1350 | |
Technical Data: | |
Manufacturer: Phases: Connection: Bearing numbers: Power Factor: Protection Class: Altitude Condition: Excitation: Insulation class/Temp. rise class: Tel. Influence Factor TIF: Tel. Harmonic Factor THF: Steady State Voltage Regulation: Alternator Capacity: Efficiency: Cooling Air Flow: | STAMFORD, UCI274C 3 3 phase 4 wire, Y type 1 0.8 IP23 ≤1000M Brushless, self-excitation H / H <50 <2% ≤±1% 100KVA 90.4% 0.37 m³/s |
Genset Technical Data: | |
Voltage Setting Range: Steady State Voltage Regulation: Transient Voltage Deviation: --100% sudden power cut: --Sudden power on Voltage Stabilization Time: --100% sudden power cut: --Sudden power on Steady State Frequency Regulation: Frequency Fluctuation Rate: Transient Frequency Deviation: --100% sudden power cut: --Sudden power on Frequency Recovery Time: --100% sudden power cut: --Sudden power on | ≥±5% ≤±1% ≤+25% ≤-20% ≤ 6 s ≤ 6 s ≤5% ≤0.5% ≤+12% ≤-10% ≤ 5 s ≤ 5 s |
PRODUCT SHOWS |
PRODUCT ADVANTAGE |
FAQ |
CONTACT US |
PRODUCT DESCRIPTION |
Engine Parameter: | |
Manufacturer/Model: Aspiration: Fuel System: Cylinder numbers Displacement: Bore x Stroke Compression Ratio: Max. Power: Governing System: | LOVOL 1006TG2A, 4 stroke Turbocharged, Air/air cooling PN Fuel Pump, 6 cylinders in-line 5.9 L 105 x 127 mm 17.5 : 1 102KW / 139HP Electrical |
Exhaust System | |
Exhaust Gas Flow: Exhaust temperature: Max. Allowed Back Pressure: | 17.9 m³/min 535 ºC 10 KPa |
Intake System | |
Max. Allowed Pressure: Gas Volume: Air Flow: | 6.2 kPa 7.8 m³/min 298 m³/min |
Fuel System | |
100% Load (Prime): 75% Load(Prime): 50% Load (Prime): | 24L/h 18L/h 12L/h |
Lube System | |
Oil Capacity: Oil Consumption: Bottom shell oil capacity: Oil Pressure at rated speed: | 16.4 L ≤4g/kw.h 14.3 L 350 kPa |
Cooling system | |
Coolant Capacity: Thermostat: Max. Water Temperature: | 26 L 82-93ºC 104ºC |
Alternator Parameter: Basic Information | |
The alternators meet the standards of: GB755, BS5000, VDE00530, NEMAMG1-22,IED34-1,CSA22.2 and AS1350 | |
Technical Data: | |
Manufacturer: Phases: Connection: Bearing numbers: Power Factor: Protection Class: Altitude Condition: Excitation: Insulation class/Temp. rise class: Tel. Influence Factor TIF: Tel. Harmonic Factor THF: Steady State Voltage Regulation: Alternator Capacity: Efficiency: Cooling Air Flow: | STAMFORD, UCI274C 3 3 phase 4 wire, Y type 1 0.8 IP23 ≤1000M Brushless, self-excitation H / H <50 <2% ≤±1% 100KVA 90.4% 0.37 m³/s |
Genset Technical Data: | |
Voltage Setting Range: Steady State Voltage Regulation: Transient Voltage Deviation: --100% sudden power cut: --Sudden power on Voltage Stabilization Time: --100% sudden power cut: --Sudden power on Steady State Frequency Regulation: Frequency Fluctuation Rate: Transient Frequency Deviation: --100% sudden power cut: --Sudden power on Frequency Recovery Time: --100% sudden power cut: --Sudden power on | ≥±5% ≤±1% ≤+25% ≤-20% ≤ 6 s ≤ 6 s ≤5% ≤0.5% ≤+12% ≤-10% ≤ 5 s ≤ 5 s |